Atypical grid usage refers to the reduction of electricity consumption during peak load times. This form of grid usage is often associated with specific requirements, risks, and opportunities, especially for companies operating in sectors with irregular energy consumption or special operating configurations.

Definition of atypical grid usage

Atypical grid usage occurs when the electricity consumption of a company or a point of consumption deviates significantly from the usual consumption patterns. Companies can benefit from this form of grid usage by consciously adjusting their loads and using flexible consumers. Grid operators define high-load time windows in which the grid load is particularly high. In particular, atypical grid usage enables companies to shift their electricity consumption outside these peak load times in order to benefit from reduced grid fees. The use of a battery storage system and energy management system can be useful in avoiding load peaks within the high-load time windows without reducing electricity consumption.

Causes of atypical grid usage

The causes of atypical grid usage can be varied:

  • Seasonal fluctuations: In winter, the grid load is increased due to higher electricity consumption and lower PV feed-in.
  • Technological changes: The use of new technologies can change the flexibility of electricity procurement and enable new applications.
  • Production shifts: Shifting production on weekends or at night can lead to atypical grid usage without energy management control.

Characteristics and examples

  • Shift outside the peak load windows: Shifting the load outside the peak load windows defined by the grid operators leads to atypical grid usage.
  • Measurability: The electricity consumption of companies is measured in a 15-minute interval using an RLM meter or intelligent measuring system.
  • Example: An industrial company that reduces its peak loads during peak load times by at least 20% can benefit from reduced grid fees and thus lower its costs.

Consequences of atypical grid usage

  • Grid relief: Atypical grid usage can lead to grid relief, especially during peak load times.
  • Grid fees: The application of atypical grid usage leads to significantly lower grid fees.
  • System efficiency: The efficiency of the electricity system increases through grid-friendly usage.

Strategies for managing atypical grid usage

  • Load management: Companies are increasingly motivated to reduce their power consumption during peak load times through specialized load management. For this purpose, forward-looking adjustments of the loads are implemented in order to comply with the criteria for atypical grid usage.
  • Energy storage: The use of buffer storage for thermal energy and flexible consumers contributes to the stability of the electricity grid.
  • Automated systems: Technologies such as the okean energy management system enable targeted control of loads during defined peak load times, which effectively ensures atypical grid usage.

Advantages and disadvantages of atypical grid usage

Advantages of atypical grid usage

  • Cost savings: Companies can realize significant savings in grid fees by reducing their peak loads during peak load times.
  • Flexibility: Companies can react more quickly to changes in the market and optimize their operating costs.

Disadvantages of atypical grid usage

  • Risk of overloads: Unforeseeable consumption peaks can strain the grid.
  • Complexity: The planning and management of atypical grid usage requires comprehensive knowledge and resources.

Summary of atypical grid usage

Atypical grid usage is a crucial aspect of modern energy supply, which brings both opportunities and challenges for companies. By using automated load management systems and identifying flexible consumers, companies can maximize the benefits of atypical grid usage while minimizing the risks. Proactive management and the application of modern technologies are necessary to realize the benefits of atypical grid usage.

Note: Please note that the Wiki entry on atypical grid usage is for information purposes only and does not replace legal advice. be.storaged GmbH assumes no guarantee for the completeness, accuracy and timeliness of the information in this entry.

be.storaged employees in a relaxed gathering in the kitchen during onboarding
Background blue

Nur noch 1 Klick zu Ihrem unverbindlichen Erstgespräch

Unser Team hilft Ihnen gerne in allen Belangen rund um nachhaltiges Energiemanagement, Batteriespeicher und Co.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
What topics are you interested in?
be.storaged Logo

Gewerbe- und Industrie­speicherlösungen

Großbatteriespeicher­lösungen

EPC

O&M

be.storaged Logo

Energiemanagement­­system

be.storaged employees in a relaxed gathering in the kitchen during onboarding
Background blue

Just one click away from your non-binding initial consultation

Our team will be happy to assist you with all aspects of sustainable energy management, battery storage, and more.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
What topics are you interested in?

Download with just 1 click:

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
be. Magazine on the energy industry from be.storaged
be.storaged Logo

Energy management system

be.storaged Logo

Commercial and industrial storage solutions

Large-scale battery storage solutions

EPC

O&M